VeroLine IP-E (Low Flow, VSD)

In-line Design

Electronically controlled glanded single pump in in-line design with flange connection and automatic power adjustment

VeroLine IP-E (Low Flow, VSD)

Technical Data:

  • Permissible temperature range:
    • -20 °C to +120 °C
  • Mains connection:
    • 3~400 V ±10 %, 50 Hz
    • 3~380 V -5 % +10 %, 60 Hz
  • Protection class IP 55
  • Nominal diameter DN 32 to DN 80
  • Max. operating pressure of standard version: 10 bar (special version: 16 bar)

  • Energy savings due to integrated electronic power adjustment
  • Optional interfaces for bus communication using plug-in IF-Modules
  • Simple operation with Green Button Technology and display
  • Integrated dual pump management
  • Integrated full motor protection (PTC thermistor sensor) with trip electronics

 

Construction:

Electronically controlled glanded single pump in in-line design with flange connection and automatic power adjustment.

 

Materials:

  • Pump housing and lantern: (EN-GJL-200)
  • Impeller: PPO-GF30
  • Shaft: 1.4021
  • Mechanical seal: AQEGG; other mechanical seals on request


Application:

Pumping of heating water (acc. to VDI 2035), cold water and water/glycol mixtures without abrasive substances in heating, cold water and cooling systems.

Operating Modes:

  • Δp-c for constant differential pressure
  • Δp-v for variable differential pressure
  • PID control
  • Constant speed (n=constant)

 

Manual Functions:

  • Differential pressure setpoint setting
  • Setting the speed (manual control mode)
  • Setting the operating mode
  • Setting the pump ON/OFF
  • Configuration of all operating parameters
  • Fault acknowledgement

 

Manual Operation Level:

  • Green button and display

 

External Control Functions:

  • "Overriding Off" control input
  • “External pump cycling” control input (effective only in dual pump operation)
  • Analogue input 0 – 10 V, 0 – 20 mA for constant speed (DDC) and remote setpoint adjustment
  • Analogue input 2 – 10 V, 4 – 20 mA for constant speed (DDC) and remote setpoint adjustment
  • Analogue input 0 – 10 V for actual value signal from pressure sensor
  • Analogue input 2 – 10 V, 0 – 20 mA, 4 – 20 mA for actual value signal from pressure sensor

 

Signal and Display Functions:

  • Collective fault signal SSM
  • Collective run signal SBM

 

Data Exchange:

  • Infrared interface for wireless data exchange with IR-Monitor/IR-Stick
  • Plug-in position for Wilo IF-Modules (Modbus, BACnet, CAN, PLR, LON) for connection to building automation

 

Safety Functions:

  • Full motor protection with integrated trip electronics
  • Access disable

 

Dual Pump Management (twin-head pump or 2 x single pumps):

  • Main/standby operation (automatic fault-actuated switchover)
  • Pump cycling main/standby operation after 24 hours
  • Parallel operation
  • Parallel operation (efficiency-optimised peak-load activation and deactivation)

Technical Data

Wilo Pump Range

Wilo Pump Range

Wilo Pump Range

Wilo Pump Range

Wilo Pump Range

Enquire Now